Case-hardened steel, case-hardened, blackened and ground
References
The clamping height can be increased by using height adjusting cylinders EH 23310. and disks EH 1107. and EH 1108. It can be reduced by employing clamping inserts, e.g. EH 22730.
Assembly
Down-thrust clamps can be attached in two ways:
in a T-slot, using a nut for T-slots DIN 508 (EH 23010.)
with the set screw directly in the mounting plate of, for example, a fixture
The cylinder must make contact over the whole surface.
Operation
Push clamping claw backwards.
Insert workpiece.
Push clamping claw forwards.
Adjust clamping position of clamping claw using the knurled screw.
Secure / lock the clamping position using the knurled nut.
This product does not contain any substances designated as "conflict minerals" such as tantalum, tin, gold or tungsten from the Democratic Republic of Congo or adjacent countries.